At present, the company has established a Comprehensive Fire Research Center, a Large-Scale Fire Research Center, and a Testing and Analysis Center, while actively advancing the construction of the UL 9540A Laboratory and the GB 38031 Laboratory.
| Serial number | Laboratory Name | Scope of the research experiment | Research Experiments/Testing Content | Major Facilities and Equipment | Experimental/Testing Capability |
| 1 | Comprehensive Fire Research Center | It primarily undertakes research and testing on fire characteristics in the new energy, power, automotive, and marine industries; develops and tests fire‑protection products; and provides customers with a standardized facility for project research, testing, and solution validation. | In accordance with UL 9540A, UL 9540B, GB 36276, and GB/T 31458 standards, we conduct research and testing on the thermal runaway performance of lithium‑ion battery cells, modules, and packs under conditions of overcharge, thermal heating, and puncture, as well as post‑thermal‑runaway fire‑extinguishing tests. Additionally, pursuant to GB 38031, we perform safety‑performance studies and tests on electric‑vehicle traction batteries, including overdischarge, overcharge, and external short‑circuit scenarios, along with post‑thermal‑runaway fire‑extinguishing assessments. We also carry out fire‑suppression and control testing for passenger‑car components. | Adjustable DC regulated charge‑discharge instrument, heating device, needle‑punching machine, multi‑channel paperless recorder, thermal imager, gas analyzer, pressure‑sensing analyzer, oil‑immersed test transformer cabinet, hydraulic twin‑column lift, and others. | ① Specialized testing capabilities for vehicle‑level component fire and fire‑suppression control; ② Safety testing capabilities for electric‑vehicle power battery packs; ③ Thermal runaway fire‑suppression testing capabilities at the cell, module, and integrated cabinet‑battery‑cluster levels; ④ General-purpose, comprehensive, synchronous monitoring and analysis capabilities; ⑤ Typical test cases and service outcomes: The company has conducted fire‑extinguishing validation tests and comparative evaluations of the suppression effectiveness of various extinguishing agents, focusing on applications at the integrated cabinet, power‑battery, and PACK levels. Its clients span multiple sectors, including new‑energy batteries, energy‑storage system integration, telecommunications equipment, and power electronics, with a cumulative total of 48 enterprises having received relevant testing services. |
| 2 | Large-Scale Fire Research Center (certified as a UL Witness Laboratory and an authorized TÜV Rheinland laboratory) | Fundamental research on large-scale fires across various industries, R&D in fire safety engineering and related technologies, studies on fire risks associated with new energy sources and industrial applications, as well as the development and validation of standardized fire test models and simulation tools. | Research on the combustion mechanisms of various materials, fire dynamics, and heat transfer; develop standardized fire models and conduct tests in accordance with standards such as ISO 15779, UL 2775, EN 15276, AS 4487, GB 4351, XF 499.1, and XF 602; build simulation-based experimental models tailored to customers’ specific scenarios to carry out fundamental fire research and validate fire‑protection solutions. | A large fire‑extinguishing facility with a floor area of 1,500 m², measuring 60 meters in length and 24 meters in both width and height, equipped with environmental protection systems; 20-foot test standard containers; and test chambers with volumes of 129 m³, 100 m³, 50 m³, 30 m³, and 20 m³, as well as standard test chambers of various dimensions. | ① Specialized testing capabilities for new energy and industrial fire risks; ② Testing and validation capabilities for fire safety engineering and fire‑protection technology R&D; ③ Capabilities in developing standardized fire‑test models, conducting simulations, and performing compliance‑based calibration tests; ④ Large‑scale extreme‑condition testing capabilities; ⑤ Conducting fire‑burn tests and fire‑extinguishing verification tests under typical scenarios, focusing on 20‑foot and 30‑foot container‑scale energy storage systems. |
| 3 | Testing and Analysis Center (CNAS laboratory accreditation on-site audit: completed; certificate expected to be obtained by September 20) | It covers seven major domains: climatic and environmental conditions, mechanical environmental conditions, packaging and transportation environments, reliability, safety, physicochemical properties, and electromagnetic compatibility; and encompasses testing and analysis of raw materials, semi-finished products, and finished goods in areas such as fire protection, electrical and electronic equipment, new energy, software, and chemicals. | Raw materials, semi-finished products, and finished products are tested and analyzed in accordance with standards including IEC 60068‑2, IEC 60068‑3, GJB 150A, EN 15276, ISO 15779, UL 2775, UL 1581, ASTM D2436, CNS 3556, CNS 742, JIS 7212, JIS B 7757, IEC 60068, EN 54, and EN 14604. | High- and low‑temperature alternating damp‑heat test chambers, high‑temperature ventilation烘箱s, electric forced‑air temperature chambers, box‑type resistance furnaces, full‑function microcomputer‑controlled vibration tables, laser particle size analyzers, salt‑spray corrosion test chambers, standard smoke chambers, standard temperature chambers, insulation resistance testers, voltage fluctuation testers, dielectric strength testers, test power supplies, Fourier‑transform infrared spectroscopic gas analyzers, gas chromatography–mass spectrometers, and other advanced domestic and international equipment and instruments. | ① Capability for physicochemical property testing of chemical raw materials; ② Capability for safety testing; ③ Capability for environmental adaptability testing; ④ Capability for life-cycle reliability verification. |
| 4 | UL 9540A Laboratory | The entire system provides comprehensive coverage of thermal runaway and fire‑risk testing requirements across multiple levels—cell, module, unit, and installation—thereby establishing multi‑tiered, systematic, and holistic safety‑testing capabilities. | It can conduct thermal runaway and fire‑risk testing across multiple levels, from individual cells and modules to system‑level assemblies, and supports a range of analytical capabilities, including thermal‑runaway gas release characterization, gas‑composition analysis, flammability and explosion‑characteristic assessment, calorimetric analysis, and smoke‑toxicity evaluation. | An outdoor 20 MW large-scale fire‑testing system, indoor calorimetric test systems rated at 0.5 MW, 4 MW, and 10 MW, along with maintenance platforms, pipeline measurement devices, calorimetric sampling and analysis systems, and control systems; additionally, a lithium‑battery heating system, a thermal radiation flux testing system, total hydrocarbon and hydrogen analysis systems, an FTIR Fourier‑transform infrared smoke toxicity testing apparatus, a test monitoring system, an intelligent data integration and visualization system, a n‑heptane atomization calibration system, and an ignition system. At the cell level, the system is equipped with cell‑level pressure vessels, gas combustion rate testers, gas explosion characteristic testing devices, flammability limit testers, and gas chromatographs, among other analytical and auxiliary testing equipment. | The aforementioned capabilities and scope comply with the testing requirements of ANSI/CAN/UL 9540A:2026, Sixth Edition; the facility possesses end-to-end testing capabilities, covering everything from the initiation of thermal runaway in battery cells and the release of thermally generated gases to the analysis of gas composition and combustion/explosion characteristics. |
| 5 | GB 38031 Laboratory | It can comprehensively conduct thermal safety, fire, and thermal runaway tests at the cell, module, and vehicle levels. | It can meet the test requirements specified in clauses 8.1.2, 8.1.3, 8.1.7, 8.2.16, and 8.2.13 of the GB 38031‑2025 standard, while also being fully compliant with all test procedures outlined in the 2023 R1 edition of the “China Electric Vehicle Fire Safety Index Test and Evaluation Procedure.” | The main equipment includes charge–discharge systems, thermal runaway test rigs, underbody impact testers, high‑current short‑circuit test devices, and full‑vehicle test platforms (capable of triggering thermal runaway in complete vehicles), among others. | It possesses capabilities for thermal safety testing at the cell, battery pack, and vehicle levels, as well as for thermal runaway and fire testing, and for compliance with relevant standards. |